PowerSpout Blog

Rotor rubbing due to corrosion

Rotor rubbing due to corrosion
Above is a picture of a rub caused by corrosion swelling in the steel laminations behind the ferrite magnets. Such corrosion will tend to push out the magnets and cause a rub. Contact with the stator then results in the wear (polishing) of the magnets. Continue reading

PLT Install Tips

PLT Install Tips
If you make your own PVC manifold make sure you heat set the pipe so the jets are in perfect alignment, and well supported to prevent sagging over time. Continue reading